Resetting a Daikin reverse cycle air conditioner begins with isolating power at the circuit breaker and entering the remote control reset sequence. This manual fix clears most sensor faults and communication errors without tools or service calls.
Owners repeat the sequence twice if the first attempt leaves the display unchanged. The process takes eight minutes once power returns to the indoor unit.
Gather Daikin Reset Supplies Checklist
Owners need only basic items already in most homes to complete the reset on a Daikin reverse cycle air conditioner. The remote control must have working batteries because a low charge interrupts the code entry. A voltage tester confirms the breaker has fully isolated power before any further steps begin. These supplies prevent repeated trips during the procedure.
| Item | Purpose | Quantity |
|---|---|---|
| Daikin remote control | Enter reset sequence | 1 |
| AA batteries | Replace weak remote power | 2 |
| Voltage tester | Verify breaker isolation | 1 |
| Soft cloth | Clean remote contacts | 1 |
Daikin Outdoor Breaker Isolation Steps
Power isolation protects both the user and the Daikin reverse cycle air conditioner from electrical feedback during reset. Locate the dedicated breaker for the outdoor unit and switch it off for sixty seconds. Return to the indoor unit and confirm the display is blank before continuing. This step removes residual charge that can block the remote command.
Remove the battery cover on the Daikin remote control. Install fresh AA batteries if voltage reads below 1.3 volts each.
Wipe the battery contacts with a soft cloth to ensure clean connection. Test the breaker position again with the voltage tester.
A single sentence warning stands alone here. Never attempt the reset while the breaker remains live.
Execute Master Daikin Reset Procedure
The remote sequence forces the Daikin reverse cycle air conditioner to clear stored fault data. Stand within three meters of the indoor unit with the remote pointed directly at the receiver. Press the mode button and the temperature down arrow simultaneously for five seconds. Release both buttons when the display flashes twice.
Press the on/off button once to confirm the unit accepts the command. Restore power at the breaker after the indoor display goes dark.
Wait ninety seconds for the outdoor compressor to initialize. Verify normal operation by selecting a cooling or heating mode.
Daikin U0 and E7 Code Reset
Error codes on a Daikin reverse cycle air conditioner often stem from temporary sensor drift rather than hardware failure. Code U0 indicates refrigerant pressure loss that the reset can sometimes clear if the cause was a brief power fluctuation. Code E7 points to communication loss between indoor and outdoor boards. The same remote sequence resolves both when performed after full power isolation.
Owners repeat the sequence if the code returns within one hour. Persistent codes require inspection of wiring connections at the outdoor terminal block.
Maintain Reverse Cycle Performance Long Term
Regular filter cleaning prevents the Daikin reverse cycle air conditioner from triggering the same faults after reset. Remove the front panel and rinse the filters under lukewarm water every four weeks during heavy use. Dry the filters completely before reinstallation to avoid moisture-related sensor errors. Schedule annual coil cleaning to keep airflow consistent across seasons.
Troubleshoot Persistent Reset Failures
A failed reset on a Daikin reverse cycle air conditioner usually traces to a stuck relay or corroded remote receiver. Test the remote by pointing it at a phone camera while pressing buttons. Visible infrared light confirms the remote still transmits. If light appears yet the unit ignores commands, replace the receiver board on the indoor unit.
Persistent Daikin Error Codes After Reset
Contact a licensed technician when the reset sequence fails twice and error codes remain visible. Provide the exact code displayed and the model number from the indoor unit data plate. Technicians arrive with diagnostic tools that read deeper fault history than the remote allows.

Hey, I’m Jake. I focus on cooling systems at Appliance Mastery, like fridges, freezers, and air conditioners.
I’ve worked in appliance repair for more than ten years and I’m certified through NASTeC. I’ve seen just about every fridge issue you can imagine.
My goal is to help you fix problems without stress. Whether it’s a freezer that won’t cool or an AC that keeps beeping, I’m here to walk you through it.