Frigidaire Ice Maker Reset Button Location: Simple Guide With Pictures

The reset button on a Frigidaire ice maker sits on the lower front edge of the module behind the ice bin. Press and hold this button for five seconds after clearing power faults or sensor errors.

Most side-by-side and top-freezer models place the button in the same spot though exact placement shifts by production year. Users must first unplug the refrigerator to prevent shocks during access. The full process requires under ten minutes once the bin is removed and inspected for obstructions.

Frigidaire Ice Maker Reset Tool Kit

Frigidaire ice maker resets demand basic hand tools and safety items before any panel removal. Owners collect these materials to avoid mid-process interruptions that could damage internal components. A standard flathead screwdriver pries off the access cover while a flashlight illuminates the tight space behind the bin. Keep a multimeter nearby to test continuity on the control board if the button fails to respond. These items fit in a small toolbox and cost little at any hardware store.

  • Flathead screwdriver for cover removal

  • Flashlight for dark interior viewing

  • Multimeter for electrical checks

  • Clean cloth for debris wipe down

Frigidaire Power Disconnect and Ice Bin Removal

Disconnecting power protects against accidental activation of the auger motor during the procedure. Open the freezer door and empty the ice bin completely to reach the module housing without obstruction. Slide the bin forward on its rails and set it aside on a stable surface. Locate the water shutoff valve behind the refrigerator and turn it clockwise to stop flow. This step prevents leaks if the inlet valve needs later inspection.

See Also  How to Reset Clock on Frigidaire Microwave (Quick Settings Tutorial)

Frigidaire Ice Maker Reset Button Hold

The Frigidaire reset button appears as a small recessed circle on the front of the ice maker control housing. Remove the lower front panel with the screwdriver to expose the button fully. Press and hold the button for five full seconds until the indicator light flashes once. Reinstall the panel and bin after the light sequence completes. Reconnect power and wait thirty minutes for the unit to cycle.

Diagnose Common Frigidaire Ice Problems

Persistent no-ice conditions after a reset often trace to clogged water filters or frozen fill tubes rather than the control board itself. Test the inlet valve with the multimeter set to ohms to confirm it opens under 120 volts. Clear any ice buildup in the fill tube using warm water and a soft brush. These checks extend the life of the ice maker assembly without full replacement.

SymptomPrimary SuspectDifficulty
No ice after resetFrozen fill tube2
Slow productionClogged filter1
Error light stays onFaulty sensor3
Ice tastes offInlet valve debris2

Frigidaire Supply Lines Restricting Ice Maker Flow

Kinked supply lines restrict flow and trigger repeated reset needs on Frigidaire units. Trace the line from the wall valve to the refrigerator rear and straighten any sharp bends. Replace the line if it shows cracks or mineral buildup that restricts water pressure below 20 psi. Proper line condition supports consistent cube formation after each reset cycle.

Frigidaire Optical Sensor Clearing After Reset

The optical sensor on the ice maker arm detects bin level and must read clear after a reset. Shine the flashlight across the sensor eyes and confirm no frost blocks the beam. Wipe both eyes with a dry cloth if residue appears. A blocked sensor prevents the unit from resuming production even when the reset button has been pressed correctly.

See Also  Where Is the Reset Button on a Frigidaire Fridge? Complete Guide

Frigidaire Ice Maker Cycle Verification Test

Run a full harvest cycle by lowering the shutoff arm and monitoring for water fill within the first hour. Listen for the motor hum and observe cube release into the bin. Measure output after twenty-four hours to confirm at least forty cubes form under normal conditions. This final verification proves the reset addressed the original fault.

Leave a Comment